null

Syringe Filters

Item #: 21233

$77.20 - $380.02

Share this product

Syringe Filters

High quality and cost effective syringe filters are available in a broad range of membrane materials with sterile and non-sterile packaging options.

Universal Features:

  • HPLC Certified
  • Disposable
  • Luer-Lok™ and pressure fitting
  • Ultrasonically bonded for reliability
  • Filter media type clearly inscribed on barrel
  • Excellent unit-to-unit and lot-to-lot reproducibility and consistency
  • High purity virgin polypropylene housing, no dyes or pigments added
  • Every unit type is available as an individually wrapped gamma sterilized pack
  • Unique concentric funnel shaped barrel increases volume and decreases back pressure

Specific Features for each type:

Cellulose acetate (CA) - Hydrophilic

  • Very low binding capacity for proteins.
  • Material is nitrate-free making it suitable for groundwater & EPA ASTM’s.
  • For filtration under sterile conditions
  • Filtration and clarification of biological fluids, sterilization of media additives and serum
  • Sample preparation of aqueous solutions
  • For applications requiring maximum sample recovery
  • Sample preparation of protein-based HPLC solutions
  • Designed to sterilize and remove particulates from even the most viscous proteinaceous samples
  • Filtration of tissues culture media with glass fiber prefilter

Glass Fiber Prefilters

  • For viscose solutions or for turbid liquids
  • Glass microfiber prefilter raises absorption capacity and loading
  • Ideal for use as a prefilter in series with other syringe filters
  • Glass microfiber filter media enclosed in this series is binderless 1.0µm retention
  • Reduces clogging of the membrane, so ideal as a prefilter to increase throughput and flow rate
  • Ideal for dissolution testing and general filtration
  • Applicable to all membrane types, allowing higher flow rates
  • Good compatibility with strong acids, bases and organic solvents
  • Similar in composition to I.W. Tremont binderless borosilicate glass microfiber media available as disks and sheets

Mixed Cellulose Esters (MCE) - Hydrophilic

  • This membrane is recommended for all filtrations in aqueous or polar media, bacteria filtration
  • Ideal when maximum protein recovery in filtrate is crucial
  • Used for filtration and inspection of gas, oil and alcohol particulate and bacteria
  • Combined with glass microfiber prefilter, ideal for tissue culture media and sensitive biological samples
  • Sample filtration - prefilter increases yield

Polyamide/Nylon (PA) - Hydrophilic

  • Hydrophilic material; it is recommended for filtration of aqueous or organic/aqueous medium polar liquids.
  • Commonly used for general laboratory filtration and filtration of HPLC and GC samples prior to injection
  • Filtration of aqueous and organic-aqueous polar medium liquids
  • Dissolution sample analysis
  • Suitable for use with high pH samples
  • Since it binds proteins it is NOT suitable for protein recovery applications
  • With microfiber prefilter higher absorption capacity for contamination

Polyethersulfone (PES) - Hydrophilic

  • High filtration flow rates
  • An inherently low affinity for proteins.
  • Low extractables
  • Introduction of additives into tissue culture vessel.
  • Certified for Ion Chromatography
  • Final filtration of bacteriophage and infusion solutions
  • Tissue culture, proteins, buffer and nucleic acids filtration
  • Ideal for applications requiring maximum sample recovery
  • Filter hybridization solutions and probe to reduce backgrounds
  • Food, beverages and ultra pure water final filtration
  • Sterile product individually blister packed

Polypropylene (PP)

  • The polypropylene membrane is resistant to many organic solvents and slightly hydrophobic
  • Useful for aqueous and organic solutions
  • Low non-specific protein binding

Polytetrafluoroethylene (PTFE) - Hydrophilic or Hydrophobic

  • PTFE membranes are inherently hydrophobic; they are ideal for the filtration of nonpolar liquids and gases.
  • Very resistant to solvents as well as acids or bases.
  • Can be made more hydrophilic by flushing with alcohol, followed by water
  • Used for filtering and de-gassing chromatography solvents
  • Permits optimal utilization of small sample volumes
  • Excellent chemical compatibility for filtering harsh chemicals that destroy other membrane materials
  • Moisture barrier for venting applications and vacuum pump line protection
  • Ideal for aerosol sampling
  • Filter viscous organic based HPLC samples
  • After pre-wetting with alcohol, may be used for fine particle removal of aqueous and mild organic solutions in Ion Chromatography

Polyvinylidene difluoride (PVDF) – Hydrophobic

  • This membrane features a stability and hydrophobic interactions similar to PTFE.
  • Recommended especially for filtration of water-soluble oligomers and polymers, e.g. protein solutions.
  • Can also be used for the filtration of hydrophobic substances in different organic solvents.